LB-DATA LiYC12Y-TP
PUR Flexible Twisted-Pair Shielded Cable
Applications
LB-DATA LiYC12Y-TP PUR Flexible Twisted-Pair Shielded Cable is designed for use in moderate mechanical stress environments, providing solutions for data transmission, measurement, and control applications. This product is widely used in industrial automation, electromechanical equipment, machine tools, and other mechanical equipment. The twisted-pair cable reduces internal electromagnetic interference, and the tinned copper braided shield provides strong resistance to external electromagnetic interference, ensuring stable data and signal transmission.
Product Structure
Reference Standard: VDE 0812
Conductor: Multiple finely stranded bare copper wires, conforming to IEC 60228, Category 5 conductors
Insulation: High-strength HDPE
Core Twist: Twisted pairs; the twisted pair structure provides circuit decoupling (crosstalk)
Filling (optional): Cotton
Shield: Tinned copper wire braid, braid density ≥ 80%
Jacket Material: High-strength PUR
Jacket Color: RAL7001 gray and other colors
Core Color:
JZ: Black core, sequential white numbering, with a yellow-green ground conductor (on the outer layer)
JB: Colored core, with a yellow-green ground conductor
OZ: Black core, sequential white ink or laser-printed numbering, without a yellow-green ground conductor
OB: Colored core, without yellow-green ground wire
Technical Parameters
Rated Voltage: 300/300V
Test Voltage: 2000V
Rated Temperature: -20°C to +70°C
Minimum Bend Radius:
Mobile Installation: When travel distance < 10 meters, bend radius is 12 x D (cable outer diameter)
When travel distance ≥ 10 meters, bend radius is 15 x D (cable outer diameter)
Mobile Characteristics: Laying travel distance: 80 meters, acceleration 50 m/s², moving speed ≤ 5 m/s
Bending Life: 30 cycles/minute, >6 million cycles
Operating Temperature:
Fixed Installation - 40°C to +80°C
Mobile Installation - 30°C to +70°C
Outer Jacket Oil Resistance: Complies with IEC 60811-2-1
Environmental Requirements: RoHS and REACH Compliant
Flame Retardant: Complies with IEC 60332-1-2
Product Features
Small cable outer diameter saves installation space.
Excellent mechanical properties.
Excellent internal and external electromagnetic interference resistance.
Suitable for flexible applications.
Specialized structural design and materials enhance wear and bending resistance.
Limited oil resistance. Complies with DIN EN 50290-2-22.
| Product Code | Number of cores × cross-sectional area n*mm² | Approximate outer diameter of cable | Approximate copper usage | Approximate cable weight |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-002.02 | 2*2*0.2 | 6.8 | 21.2 | 50 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-002.03 | 3*2*0.2 | 7.1 | 25.7 | 59 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-002.04 | 4*2*0.2 | 7.4 | 31.0 | 71 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-002.05 | 5*2*0.2 | 8.8 | 36.6 | 91 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-002.06 | 6*2*0.2 | 9.5 | 42.1 | 103 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-002.07 | 7*2*0.2 | 10.6 | 47.6 | 125 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-002.08 | 8*2*0.2 | 10.6 | 51.1 | 133 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-002.09 | 9*2*0.2 | 12.1 | 58.8 | 153 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-002.101 | 10*2*0.2 | 12.3 | 62.9 | 162 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-002.12 | 12*2*0.2 | 13.0 | 70.9 | 191 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-002.15 | 15*2*0.2 | 14.7 | 85.1 | 239 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-002.16 | 16*2*0.2 | 14.7 | 88.6 | 246 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-002.18 | 18*2*0.2 | 15.4 | 97.7 | 268 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-002.20 | 20*2*0.2 | 15.8 | 105.7 | 287 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-003.02 | 2*2*0.3 | 7.2 | 26.1 | 57 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-003.03 | 3*2*0.3 | 7.6 | 32.5 | 69 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-003.04 | 4*2*0.3 | 8.3 | 39.7 | 91 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-003.05 | 5*2*0.3 | 9.4 | 47.2 | 106 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-003.06 | 6*2*0.3 | 10.2 | 54.7 | 122 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-003.07 | 7*2*0.3 | 11.3 | 62.3 | 147 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-003.08 | 8*2*0.3 | 11.3 | 67.6 | 157 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-003.09 | 9*2*0.3 | 13.3 | 77.5 | 192 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-003.10 | 10*2*0.3 | 13.5 | 83.4 | 204 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-003.12 | 12*2*0.3 | 14.3 | 95.2 | 240 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-003.15 | 15*2*0.3 | 15.7 | 115.2 | 284 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-003.16 | 16*2*0.3 | 15.7 | 120.5 | 293 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-003.18 | 18*2*0.3 | 16.5 | 133.4 | 321 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-003.20 | 20*2*0.3 | 16.8 | 145.1 | 344 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-005.02 | 2*2*0.5 | 8.1 | 35.8 | 73 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-005.03 | 3*2*0.5 | 9.2 | 48.2 | 100 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-005.04 | 4*2*0.5 | 10.5 | 59.7 | 141 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-005.05 | 5*2*0.5 | 11.9 | 71.5 | 166 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-005.06 | 6*2*0.5 | 12.8 | 83.2 | 191 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-005.07 | 7*2*0.5 | 14.2 | 95.1 | 229 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-005.08 | 8*2*0.5 | 14.2 | 104.0 | 245 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-005.09 | 9*2*0.5 | 16.7 | 119.0 | 296 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-005.10 | 10*2*0.5 | 17.0 | 128.7 | 315 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-005.12 | 12*2*0.5 | 17.5 | 148.1 | 353 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-005.15 | 15*2*0.5 | 19.7 | 180.2 | 439 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-005.16 | 16*2*0.5 | 19.7 | 189.1 | 456 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-005.18 | 18*2*0.5 | 21.1 | 209.9 | 519 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-005.20 | 20*2*0.5 | 21.6 | 229.3 | 558 |
| Product Code | Number of cores × cross-sectional area n*mm² | Approximate outer diameter of cable (mm) | Approximate copper usage (kg/km) | Approximate cable weight (kg/km) |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-075.02 | 2*2*0.75 | 9.8 | 39.8 | 98 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-075.03 | 3*2*0.75 | 10.3 | 50.3 | 120 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-075.04 | 4*2*0.75 | 10.9 | 62.1 | 146 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-075.05 | 5*2*0.75 | 12.8 | 74.1 | 184 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-075.06 | 6*2*0.75 | 13.9 | 86.2 | 211 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-075.07 | 7*2*0.75 | 15.0 | 98.4 | 239 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-075.08 | 8*2*0.75 | 15.0 | 107.3 | 257 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-075.09 | 9*2*0.75 | 18.0 | 122.9 | 327 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-075.10 | 10*2*0.75 | 18.3 | 132.6 | 349 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-075.12 | 12*2*0.75 | 18.9 | 152.2 | 391 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-075.15 | 15*2*0.75 | 21.3 | 184.8 | 487 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-075.16 | 16*2*0.75 | 21.3 | 193.8 | 505 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-075.18 | 18*2*0.75 | 22.4 | 214.9 | 554 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-075.20 | 20*2*0.75 | 22.9 | 234.4 | 597 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-010.02 | 2*2*1.0 | 11.0 | 60.6 | 129 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-010.03 | 3*2*1.0 | 11.6 | 80.0 | 163 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-010.04 | 4*2*1.0 | 12.8 | 100.9 | 213 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-010.05 | 5*2*1.0 | 14.8 | 122.2 | 266 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-010.06 | 6*2*1.0 | 16.1 | 143.5 | 307 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-010.07 | 7*2*1.0 | 17.7 | 164.7 | 365 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-010.08 | 8*2*1.0 | 17.7 | 182.4 | 394 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-010.09 | 9*2*1.0 | 20.4 | 207.7 | 451 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-010.10 | 10*2*1.0 | 21.1 | 226.3 | 503 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-010.12 | 12*2*1.0 | 21.4 | 263.4 | 569 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-010.15 | 15*2*1.0 | 24.5 | 323.0 | 706 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-010.16 | 16*2*1.0 | 24.5 | 340.6 | 736 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-010.18 | 18*2*1.0 | 26.2 | 379.6 | 834 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-010.20 | 20*2*1.0 | 26.8 | 416.7 | 902 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-015.02 | 2*2*1.5 | 12.4 | 81.2 | 170 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-015.03 | 3*2*1.5 | 13.1 | 109.6 | 216 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-015.04 | 4*2*1.5 | 14.8 | 139.7 | 281 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-015.05 | 5*2*1.5 | 16.2 | 170.2 | 335 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-015.06 | 6*2*1.5 | 17.6 | 200.7 | 388 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-015.07 | 7*2*1.5 | 19.4 | 231.3 | 460 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-015.08 | 8*2*1.5 | 19.4 | 257.7 | 500 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-015.09 | 9*2*1.5 | 23.2 | 292.7 | 614 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-015.10 | 10*2*1.5 | 23.5 | 320.3 | 659 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-015.12 | 12*2*1.5 | 24.3 | 375.3 | 749 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-015.15 | 15*2*1.5 | 27.4 | 462.1 | 927 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-015.16 | 16*2*1.5 | 27.4 | 488.5 | 968 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-015.18 | 18*2*1.5 | 28.8 | 545.5 | 1067 |
| LB-DATA LiYC12Y(TP)-300JZ/JB/OZ/OB-015.20 | 20*2*1.5 | 29.9 | 600.5 | 1185 |
Flexible Twisted Pair Shielded Cables are designed to deliver high-speed, reliable data transmission with minimal electromagnetic interference (EMI) and crosstalk. Combining twisted pair construction with robust shielding, these cables maintain signal integrity and ensure long-term performance in industrial, commercial, and networking environments. Their flexibility allows for easy routing through confined spaces, making them ideal for automation systems, telecommunications, electronic devices, and data centers.
Proper installation is key to achieving optimal performance from flexible twisted pair shielded cables. Below is a schematic overview:
Installation Diagram Overview:
Identify cable path and routing constraints.
Ensure connectors align with corresponding ports.
Maintain minimum bend radius to avoid signal degradation.
Properly secure cable with clips or ties to prevent movement.
Diagram Placeholder: [Insert schematic showing cable routing, connectors, and minimum bend radius]
Safety is critical when installing and using flexible twisted pair shielded cables.
Ensure power is off before connecting or disconnecting cables.
Avoid exposure to high-voltage sources.
Do not exceed recommended bend radius.
Avoid pinching or crushing the cable.
Use cable management accessories to prevent strain.
Keep cables away from water, corrosive chemicals, and excessive heat.
Avoid direct sunlight and UV exposure for non-UV-resistant jackets.
Wear gloves when handling sharp connectors.
Use safety glasses in environments with potential debris.

Following proper installation procedures ensures optimal performance and longevity.
Verify cable type, length, and shielding.
Inspect connectors and cable ends for damage.
Plan cable path avoiding interference from high-power lines.
Maintain recommended bend radius throughout the route.
Insert cable into connector, ensuring proper alignment.
Engage locking mechanisms or clips to secure the cable.
Use cable ties or clips to prevent movement.
Avoid tight bundling that can compromise shielding effectiveness.
Conduct continuity, resistance, and signal integrity tests.
Verify performance using network analyzers or relevant test equipment.
| Step | Action | Notes |
|---|---|---|
| Preparation | Verify cable type and inspect connectors | Prevents installation errors |
| Routing | Plan path and maintain bend radius | Avoids signal degradation |
| Termination | Properly insert and secure connectors | Ensures stable connection |
| Securing | Use ties/clips | Prevents cable movement |
| Testing | Continuity and signal integrity check | Confirms optimal performance |
Reliable technical support ensures proper installation, troubleshooting, and long-term customer satisfaction.
Guidance on routing, connector termination, and shielding handling.
Recommendations for minimizing EMI and signal loss.
Diagnose signal issues, crosstalk, or interference.
Provide solutions for repair, replacement, or re-routing.
Access to technical datasheets, wiring diagrams, and certification documents.
Detailed installation manuals and compliance guidelines.
Email, phone, and live chat support.
Dedicated B2B account managers for bulk orders and custom solutions.
Standard warranty for manufacturing defects.
Clear policies for replacement, returns, and service requests.
Flexible Twisted Pair Shielded Cables are widely used across multiple industries:
Industrial Automation: PLC systems, robotic arms, and machinery communication.
Telecommunications: Network switches, routers, and data centers.
Medical Equipment: Diagnostic devices, imaging systems.
Consumer Electronics: Computers, printers, AV systems.
Transportation: Automotive networking, rail communication, and control panels.
Flexible Twisted Pair Shielded Cables offer reliable, high-speed, and interference-free connectivity for modern applications. Following proper installation procedures, adhering to safety guidelines, and leveraging technical support ensures optimal performance and long-term reliability. Choosing certified, high-quality flexible twisted pair shielded cables helps businesses maintain operational efficiency, reduce downtime, and comply with international standards.
RELATED
Bu web sitesi, web sitemizde en iyi deneyimi yaşamanızı sağlamak için çerezleri kullanır.